Tag Archives: Fire

Destruction of a Power Plant God

Sometimes we unknowingly end up worshiping things we never intend.  It isn’t until those things are destroyed before we realize what has happened.  We have a natural tendency to worship something.  It’s built into our DNA to worship God just as sure as the God Particle converts energy into matter and subsequently atoms into earth and water.  I’m not sure when my obsession began, but I definitely know the day when it was destroyed.  August 5, 1996.

The day of realization began as a normal day, as Scott Hubbard and I were driving to the plant.  It seemed like an extra dark morning considering it was the middle of the summer.  Perhaps it was because by this time we were working four tens, which meant we arrived at the plant before 7:00 am so we left Stillwater, Oklahoma at 6:15 to drive to the coal-fired Power Plant in North Central Oklahoma.

When we topped the overpass to the turnpike at 6:32 we thought we could see something strange at the Power Plant off in the distance.  The sun was going to rise in the next few minutes (at 6:42), yet, the sky seemed darker than usual.  It must have been a cloudy morning.

Power Plant at sunset

Power Plant at sunset (only we were arriving before sunrise)

We thought we could see red and blue flashing lights coming from one end of the plant.  It was only momentary, because once over the overpass, we were too low to see that section of the plant.  We weren’t really sure what we had seen.  It became even more confusing as we approached the entrance to the plant.

There seemed to be a little more activity happening at the front gate than usual.  there was a guard or an operator standing out there.  He waved us through the gate.  about 300 yards past the main gate, we had a clear view of the plant grounds laying before us as we made our way to the parking lot.  It was here that the significance of the flashing lights suddenly caused us to gasp. We were stunned into silence.

The area around the Unit 1 main power transformer was flashing with the red and blue lights of several fire trucks.  They seemed to be pulling away just about that time.  Some of the siding on the Turbine-Generator room was missing, some was blackened from smoke as it had poured out of the windows along the turbine room floor.  The real shock to me came as we approached the parking lot and I looked up through where a window used to be and I could see the sky.  I could see the sky where the T-G roof should have been.

We were directed to go into the maintenance garage to avoid the fire trucks who that were backing away.  We met with our team and Alan Kramer told us that there had been an explosion during the night when an overspeed test was being performed on the Unit 1 Boiler Feed Pump Turbine (BFPT).  The number one question we all wanted answered was quickly given to us…. No one was hurt in the explosion.

Alan mentioned that in our recent fire fighter training, we had learned that a large percentage of companies that have a major fire (such as ours) goes out of business within the next year.  That was not going to happen to us even though the damage was extensive.  Our job was to put everything back to the way it was before the fire.

Here is the story as it happened, as much as I know:

The explosion occurred when an operator (I’ll let one of the operators remind me who it was) was running an overspeed test on the BFPT.  Suddenly he heard a loud pop and then the turbine winding up out of control.  He took off running and was around the corner of a concrete pillar when the turbine exploded.  The turning gear shot out like a top and flew across the mezzanine floor, hit the corner of the north stairway, and still spinning like a top, tore up the stairway as it made the turn halfway down and ended up in middle of the the T-G basement where it finally came to rest.  This turning gear weighs somewhere in the ballpark of a thousand pounds (I’m guessing).

Turning Gear

Turning Gear

At this point steam was shooting out of the Boiler Feed Pump Turbine.  The oil pumps that keep the bearings lubricated were spraying oil into the steam which burst into flames.  The flames shot up to the concrete floor 40 feet above.  The fire was so hot that it melted the metal structure holding up the floor and the rebar in the concrete.  The Turbine Room Floor literally melted away as the oil fire shot the flames up toward the roof another 80 feet above the turbine room floor  melting the roof as if it was butter.  The asbestos siding on the T-G floor was falling off because the bolts that held them to the brackets literally melted away.

The same reservoir that feeds the oil to the the Boiler Feed Pump Turbine bearings also fed the Main Turbine Generator.  This is the same generator that makes the electricity that causes the light bulb to glow in your house when you turn it on.  The Main Turbine Generator tripped when the explosion occurred, as it should.  As it slowed down to a stop, the oil for the bearings was all gone.  It had been creating the large fire ball that was melting down the T-G floor.

Normally, when the Turbine-Generator comes to a stop, it is put on a turning gear while the shaft cools down otherwise the shaft will become warped under it’s own weight.  The Turning gear slowing rotates the turbine for a day or so while it cools.  Without bearing oil, the turning gear would not be able to turn the turbine generator.  The bearings require a layer of oil to function properly.

Unit 1 Turbine-Generator

Unit 1 Turbine-Generator

Charles Patton, one of the Maintenance foremen was called out, and he took cans of STP Oil Treatment and for hours poured them onto the bearings and manually rotated the 50 ton turbine generator (Ray, help me out with the actual weights).  Through the heroic efforts of Charles and others that were there to help, the Turbine Generator was spared from even more damage.

Charles Patton

Charles Patton

By the time we arrived that morning, the fire was out, things were cooling down.  Unit 2 was still running, and it was our job to keep it going.

Unit 2 Turbine-Generator

Unit 2 Turbine-Generator

As I walked out onto the T-G floor everything went into slow motion.  I don’t know if that has ever happened to you before.  There have been a few times in my life when I was in a near death situation where my surroundings all seem to switch into a slow motion mode.  I think it happens because your brain kicks into high gear in order to process what is happening and to put as much effort forward as possible to avoid danger.

The first time I think that happened to me was when I was with some friends climbing around on some cliffs by the Missouri River.  One boy was falling back after the ledge he was on gave way and was going to fall most likely to his death when everything switched into slow motion even before I realized what was wrong.  I was able to make quick decisions that allowed me to push him back onto the ledge and grab onto a branch that luckily kept me from the same fate.

When I walked onto the T-G floor and saw the devastation, I think my mind was trying to take everything in all at once.  The Turbine Generator was covered in soot and debris.  I flashed back to the days when I was a janitor and used to keep the turbines waxed so that they would shine.  It was at this moment that I realized I actually worshiped the Turbine Generators in a way similar to the way the religious cult worshiped the alpha-omega doomsday bomb in “Beneath the Planet of the Apes”.

Bomb Worshipers in Beneath the Planet of the Apes

Bomb Worshipers in Beneath the Planet of the Apes

The near destruction of the Turbine Generator made me realize the importance I had placed on it.  I felt as if I had almost lost my close friend like the boy climbing on the cliff.  I used to stand on the sides of the Turbines when I was a janitor with my dust mop and after spraying furniture polish on the mop, I would caress the turbines as if I was running my fingers through someone’s hair.

Like this only with a mop handle

Like this only with a mop handle

We began the clean up by taking fire hoses and washing down the siding on the Unit 2 side to try to bring some normalcy back to a surreal situation.  The soot didn’t just wash off.  Not long after we had dragged out the fire hoses and were blasting away at the siding, Alan Kramer asked Charles Foster and I to look at the air duct to the Instrument room on the north side of the Turbine room.  The room was getting too hot and the air conditioner seemed to have frozen.

We climbed into the air duct on the roof of the instrument room and replaced the filters that were packed with soot stopping the air flow for the Air Conditioner.  This seemed like one task in 100,000 that would need to be done to put this puzzle back together again.  All the electric cables that ran through the Unit 1 Mezzanine had melted away, everything had been utterly destroyed.

The thought was too overwhelming.  I felt like Scarlet O’Hara in “Gone With the Wind” when she said, “I can’t think about that right now.  If I do, I’ll go crazy.  I’ll think about that tomorrow.”

Vivian Leigh as Scarlett O'Hara in Gone With the Wind

Vivian Leigh as Scarlett O’Hara in Gone With the Wind

With everything on the T-G floor covered in soot, everyone was quickly black from head to toe.  Are clothes were now black.  We looked like Johnny Cash impersonators

Johnny Cash Man in Black

Johnny Cash Man in Black

literally with Al Jolsen Black Face as the soot was pitch black.

Al Jolson dressed in Black Face

Al Jolson dressed in Black Face (Google Image)

We had just climbed out of the air duct and were making our way to the electric shop when Glenn Rowland approached me and said, “You Lucky Dog!”  I thought he must be making a comment about my appearance seeing how I was covered in soot.  Then he explained.  “For the next 10 weeks you have to report to Oklahoma City to work on an SAP project.  You’re a lucky dog because you are going to miss all the fun of cleaning up this mess.”

Did I ever mention that I’m one of the luckiest people in the world?  Well.  I am.  I had just come to grips with my false God, and now I had been rescued from two and a half months of working in soot and grime to go work in an air conditioned office building in Oklahoma City.

Now for the hard part of the story to write about:

So, why did the Boiler Feed Pump Turbine fail the overspeed test?  What happened to cause the explosion?

The first attempt to place the blame where it didn’t belong was to blame Sonny Kendrick who had worked on the controls during the last outage.   The same person that would accuse me of purposely causing any little opacity problem on the precipitator even when I was on vacation, was now blaming Sonny Kendrick for the multi-million dollar destruction of the Turbine Room Floor.

Sonny Kendrick must have looked like an easy target.  A soft-spoken man that works alone most of the time.  No one really understands some of the things he works on.  Maybe they thought he wouldn’t be able to explain the changes he had made to the controls in enough detail in order to blame him for the explosion.  I use the word “target” because someone else had to be “blamed” for the explosion than the person responsible.  The person they picked as the “fall guy” was Sonny Kendrick:

Sonny Kendrick

Sonny Kendrick

You see… someone was directly responsible for the explosion.  Someone who continuously used “Risk Management” as an excuse to cut corners.  I wonder if everything was completely on the unconscious level, or did this person ever realize the impact of his decisions.  You see, I haven’t completely decided.

There appears to have been a conspiracy to cover up the truth about the explosion that took three months to recover.  The first clue was to try to blame Sonny Kendrick without any proof.  I don’t know if Sonny was eventually cleared as the fall guy because he was able to clearly show how all of his wiring changes had no impact on an overspeed test, or someone who knew about the actual cause threatened to come out with the truth if they continued to pursue Sonny as the fall guy.  You see… there was more to this equipment failure than met the eye.

The turbine exploded because the coupling to the pump shattered.  That’s the part that connects the steam turbine to the boiler feed pump.  When the coupling broke the turbine, no longer having any resistance, began to rotate at a rate much faster than it was ever designed to rotate until it flew apart.

A large coupling

A large coupling

It was known at the end of the last outage that the coupling was damaged.  It would have delayed bringing the unit online another 2 or 3 days in order change out the coupling.  In the name of “Risk Management” it was decided to “risk it” until the next outage.  The decision was made without using any type of risk assessment tool… obviously.

I know about the conversations that took place because one of the people involved confided in me.  The person that told me the details of the conversations said that even under oath he would never tell anyone else the truth.  This is the second clue that made me think that a concerted effort was made to cover up the knowledge that it was known that a faulty coupling was operating on the Boiler Feed Pump Turbine and it had been decided to leave it in place.  You see… everyone who was on the team that found the damage knew about it.

The third clue this was a “conspiracy to cover up the truth” was that when an investigation was performed to look into the cause of the explosion, the person responsible for keeping the bad coupling in place played a major role in the investigation.  Like the Fox guarding the Hen House.

Because the truth about the coupling never came to light, the insurance company ended up paying the entire bill for the outage.  It was ruled as “equipment failure”.  Our plant manager Bill Green remarked one day that we actually came out ahead when the insurance company paid for the outage, because they paid our lost revenue without taking all the operating costs into account.

I know sometimes that things just happen and sometimes bad things happen.  Sometimes when everything is done correctly, something still goes wrong.  I know that.  That is why when this explosion first happened it made me step back and think twice about the dangers lurking around a Power Plant.  A tremendously large amount of energy is being converted from coal into electricity.  Somewhere, some time, something is going to go wrong and someone is going to be hurt or killed.

That is also why when this explosion happened, it never occurred to me to place the blame on anyone.  To me it was just one of those things that happens every now and then.  My bubble of innocence was burst the day I heard about the decision to keep a defective coupling in place on such an important piece of equipment.

On one hand I was angry that someone would make a decision that could have ended with the death of an operator, on the other hand, I was relieved to know that accidents like this don’t just happen.  It was only when someone decided to cut corners that this explosion occurred.  It gave me a little of my faith back in the system.  When things are done right, we can work safely without the fear that something is likely to explode in our face.

All right, so I never really worshiped the Turbine Generator.  I just exaggerated that part a bit.  But let me ask this question… Who in this story did?  Who was it that was willing to sacrifice the life of an operator to keep from delaying the “go-live”?  Who thought that having the Generator produce electricity two or three days sooner than it should have been was more important?  That is the person that really needs to re-evaluate their priorities and take another look at which God they worship.

The question is never, “Is there a God?”  The real question is “Which God do you worship?”

Advertisements

Hot Night on the Power Plant Precipitator

Scott Hubbard and I weren’t too sure why we had been called out that night when we met at the Bowling Alley on Washington Street at two o’clock in the morning in Stillwater Oklahoma to drive out to the coal-fired Power Plant in North Central Oklahoma.  Something about a fire on the top of the precipitator.

I was glad that Scott was driving instead of me when I climbed into his pickup and he began the 20 mile journey up Highway 177.  I wasn’t quite awake yet from the phone call at 1:45 am telling me that there was a fire on the Unit 1 precipitator roof and they were calling Scott and I out to put it out.  I figured if there was a fire it should be put out long before the 45 minutes it takes me and Scott to arrive at the plant.

We had all been trained to fight fires this size, so it didn’t make sense why we had to go do this instead of the operators.

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

My head was still swimming from the lack of sleep when we arrived at the plant, and headed to the Control Room to find out more about the fire we were supposed to fight.  The Shift Supervisor explained that there was an oil fire under one of the high voltage transformers next to some high voltage cables, and the operators that were on duty didn’t feel comfortable climbing under the transformer stands to try and put it out because of high voltage cable tray that ran alongside the fire (ok, now it made sense.  Electricity was involved.  Electricians had to work on anything that had an electric cable attached even if it was a fire).

The size fire extinguisher you would find in your home

The size fire extinguisher you would find in your home.  The ones we used were bigger

The operators had already brought a number of fire extinguishers appropriate to putting out an oil fire to the precipitator roof, and they had an SCBA (Self Contained Breating Apparatus) waiting there as well.

Man wearing an SCBA

Man wearing an SCBA from Google Images

Scott and I went to the Electric Shop to get a couple of pairs of asbestos gloves just in case we needed them.

Asbestos Gloves worn when putting hot bearings on a motor shaft (for instance)

Asbestos Gloves worn when putting hot bearings on a motor shaft (for instance)

When we arrived on the precipitator roof we could smell the fire smoldering right away.  The operator explained that some oil soaked insulation was on fire under the transformer stand for Transformer 1G9 and that he had tried to put it out using the extinguisher, but since the transformer oil was soaked into the bricks of insulation, it didn’t seem to do any good.

The transformer stands are about 18 inches tall, so climbing under them reminded me of the time I was sandblasting the water treatment tanks and Curtis Love turned off my air (see the post:  “Power Plant Safety as Interpreted by Curtis Love“).  This time I had a self-contained breathing apparatus, so I was in control of my own air… only there would only be about 30 minutes of air in the tank.

After assessing the situation Scott and I decided that the only way to put the fire out was to remove the blocks of insulation that were burning.  This meant that I had to lay down under the precipitator transformers and come face to face with the burning insulation and pull them out while wearing the asbestos gloves and put them in a barrel.

The plan was that we would then lower the 55 gallon barrel down to the ground and extinguish the fire by filling the barrel with water.

Barrel of LPS Electro Contact Cleaner

A barrel this size, only it was empty and the top was removed

The precipitator is on the outlet end of the boiler.  The boiler exhaust blows through the precipitator and the ash in the exhaust is removed using static electricity generated by the large transformers on the precipitator roof using up to 45,000 volts of electicity.  When the precipitator is on, the roof is generally a warm place to be.

When a person is laying on the insulation under a transformer, the temperature is somewhat higher as the heat is trapped in the enclosed space between two enclosures called “Coffin Houses” (how appropriate).  When the insulation is soaked with burning oil, the temperature seemed to rise significantly.  Luckily the insulation was not fiberglass as you may have in your attic, because I was wearing nothing but a tee shirt and jeans.  So, I was not subject to the itching I would have if the insulation had been fiberglass.

I had turned the air on the SCBA without using the “Postive Pressure” setting.  That meant that when I inhaled, I pulled air from the air tank, but the air didn’t apply pressure on the mask to keep out the bad air.

I did that because, this looked like it was going to be a long job and I wanted to conserve the air in the tank, and I found that on this setting I was not breathing the smoke pouring up around my face.  Otherwise I would have reached down to the valve on my belt and changed the setting to positive pressure.

I kept wondering while I was lying there with my face a few inches from the smoldering blocks of insulation why I was so calm the entire time.  The hot temperature had caused my sweat reflex to pour out the sweat so I was quickly drenched.  I would just lay my head on the insulation as I reached into the hole I was creating and pulled a glowing brick of insulation out using the asbestos gloves.

I knew I was only half awake so I kept telling myself… “Pay attention.  Work slowly.  One step at a time.  I tried to work like Granny would when she was digging Taters on the Beverly Hillbillies (see the video below):

In case you are not able to view the video above, try this link:  “Granny Digging Taters“.

It’s funny when you’re half dreaming the various things that come to mind.  I’m not sure how picking up smoldering bricks of insulation translated in my mind to Granny teaching beatniks how to pick “taters”…. but it did.

There was also something about this that reminded me of eating chocolate…. oh wait… that was probably left over from the dream I was having when the phone first rang back at the house.

For the next hour or so, I filled the barrels with the burning insulation and then lowered them down to the alleyway between Unit 1 and 2.  During this time I was still groggy from the lack of sleep and the entire process seemed like a dream to me.

I remember lying on my stomach next to the burning insulation.  Pulling the blocks out one at a time, layer by layer until I reached the precipitator roof underneath.  I placed each block of smoldering insulation in the barrel that had been lowered down by an overhead chain-fall near me.

When the barrel was about 3/4 full, we would work the chain fall over to the motorized hoist that would lower it down to the pickup truck bed 100 feet below.  When the barrel left the confines of the precipitator roof and the night air blew over the top of it, the insulation would burst into flames.  By the time the barrel landed in the back of the pickup truck the flames would be lighting up the alley way.

Scott doused the flames with a hose and an extinguisher and hauled the barrel of insulation off to a hazardous waste bin while I repeated the process with the next barrel that Scott attached to the hoist.

By the time we were through I smelled like something that crawled out of a damp fireplace.  My shirt and jeans were soaked with sweat and caked with pink insulation.  The SCBA was out of air after using it for an hour and we were ready to go home.

The operators said they would bring the empty extinguishers back to the plant and send the SCBA off to have it recharged.  We checked back in with the Shift Supervisor in the control room and told him we were heading for home.

I don’t remember which Shift Supervisor it was, though Gary Wright comes to my mind when I think about it.

Gene Day is the one standing on the right with the Orange shirt.

Gary Wright is the red haird man in the front row with the big round glasses

I don’t remember which operator was helping us on the precipitator roof either.  I would usually remember those things, but like I said, I was still dreaming during this entire process.

Normally at this time, since it was close to 3:30 in the morning, we would opt to stay over and just do some odd jobs until it was time to start work because the 6 hour rule would still require us to come back to work at the regular time (see the Post: “Power Plant Black Time and Six Hour Rule“).  Scott and I decided that we both needed a good shower and if we could catch even one hour of sleep before we had to head back out to work, that would help.

So, we climbed back into Scott’s truck and headed back to Stillwater to the bowling alley where I had left my car.  I don’t remember the drive home.  I don’t even remember taking off my shirt and jeans in the utility room where I walked in the house and placing them in the washing machine straightaway… though that’s what I did.

I know I took a shower, but all that was just part of the same dream I had been having since the phone rang earlier that night.  Usually I didn’t have trouble waking up when the phone rang in the middle of the night, but for some reason, this particular night, I never fully woke up.

Or… maybe it’s something else….  Could I have dreamed the entire thing?  Maybe I never did receive that call, and we didn’t have to go out to the plant in the middle of the night to put out a fire.  I mean… how crazy is that anyway?  Does it make any sense?

I suppose I will have to rely on Scott Hubbard to confirm that we really did fight that fire.  How about it Scott?

Scott Hubbard

Scott Hubbard

As Bill Gibson asked one time…. “Is the Fact Truer than the Fiction?”

Power Plant Men Fighting Fires for Fun

Originally Posted October 5, 2012:

The Coal Fired Power Plant where I worked first as a summer help, then as a janitor, a labor crew hand and finally as an Electrician is located about 20 miles north of Stillwater, Oklahoma.  It just so happened that Oklahoma State University in Stillwater has one of the leading Fire Protection and Safety schools in the country.  They offer Fire Service Training for companies who need to train their employees how to fight fires.  As a summer help I was fortunate enough to take the onsite training that they provided at the power plant about every other summer to train the employees how to put out difficult fires.

It does sound like a good idea considering that there was all this coal laying around that had the habit of spontaneously igniting into smouldering embers that could easily lead to a large raging ball of flames.  In fact, the Coal Yard heavy equipment operators had to driver their large dirt movers over and over the coal on the coal pile to pack it down because if it was exposed to too much air, it would develop hot spots that would turn into smouldering piles of coal that were nearly impossible to put out.

Dirt Mover full of coal

I have seen a spot smouldering on the coal pile where a water wagon would drench it with water over and over.  That only seemed to keep it from spreading as fast.  The only way to deal with it was to drag the burning coal off of the pile and let it burn itself out.

You would think that the OSU Fire Training Service would do a good job of teaching the employees the proper use of the fire extinguishers, and they did.  The plant was loaded with Fire Extinguishers.  As a summer help and labor crew hand, we would have to do a monthly inspection of all the plant extinguishers to check their pressures an initial the inspection sticker showing that we had been by to check it.  This was a practice that would later change to once each quarter when the Power Plant Men were strung out too thin and the labor crew no longer existed.  Even later, the operators inspected them as they made their rounds, since they walked by them during their shifts anyway.

The plant had more than just the regular chemical fire extinguishers, it had the larger roll-around type in a few places as well:

More than what is needed in your average kitchen

The Fire Training Service trained us to use this as well.  Actually, they motivated us to go out and buy fire extinguishers to put in our own homes.  Which came in handy for me one year when an air condition repairman was using a blow torch in my house to cut out the cooling coils but forgot to take out the filter first.

The moment I saw him light up his torch, I pulled out the extinguisher from under the sink and set it on the counter.  As I watched him, he suddenly started jerking back and forth.  I figured something was up, so I pulled the pin, and when he was finally able to pull the burning filter out of the air duct, I was ready to blast it with the extinguisher.  So, I gratefully thank the electric company for properly training us to use the handy dandy fire extinguishers that you might use around the house.

The size fire extinguisher you would find in your home

The size fire extinguisher you would find in your home

One important thing that you learn about the little extinguishers in your house is that they don’t really go very far before they run out of chemicals.  So, you have to get the job done quickly while the fire is still small and manageable.

When I first heard that we were going to be trained to fight fires the second summer I was at the plant as a summer help, I was pretty excited.  Wow… Great!!!  Fight Fires!  That sounds fun.  A day of watching safety videos and playing with fire extinguishers.  I didn’t realize at the time that there was a reason why OSU Fire Training Service was the best fire training school in the radius of about 1,000 miles.

Sure.  We watched the training videos.  We learned all about proper fire extinguisher care and maintenance.  We heard stories about how small fires turned into raging infernos that burned companies right out of business.  One thing I remember is that some large percentage of companies that have a major fire are never able to recover to the point that they go completely out of business.

If you need the exact percentage, I suggest you call up the OSU School of Fire Protection and Safety.  They probably have the latest statistic printed on their school lunch napkins, because these guys eat, drink and sleep fire safety.

Then, after they had impressed us with their Fire Safety Prowess, they said, “Let’s take about a 15 minute break, and we will meet outside just north of the water treatment plant where we will resume your lessons.  Oh, and bring your rubber boots and maybe a rain suit.”  Rain Suit?  What?  It’s about 100 degrees outside.  “I wouldn’t mind getting a little wet”, I thought to myself. — The simpleminded summer help that I was at the time.

I would describe in detail to you how they had this obstacle course of staircases and pipes and other metal structures all sitting in a big tray.  It’s enough to say that it was quite a tangled mess of a contraption.

“Interesting.” I thought… Are we going to climb the staircase  and shoot the fire from up above with our handy dandy fire extinguishers which were lined up in a row off to one side?  Climbing over pipes to fight a fire under the stairs maybe…  Do we get to use the big roll around fire extinguisher that was there too?  This looks like it might be fun.

That was when the fun began.  One of the trainers turned a valve, and then I realized that there was a fairly large tank there also that was hooked up to the pipes that wound around the mocked up structure of a stairway and other obstacles in the large tray.  As he turned the valve, what looked like diesel or kerosene some petroleum product  came spraying out of various holes in the piping spraying everything in the tray drenching it with fuel.

This other guy had a long rod that he had lit like a large lighter only it was giant size, and after the fuel had been spraying out for a while, he lowered the flame down into the tray that now was beginning to fill up with some kind of oily substance.  He lit it and the flames quickly spread over all the structure.  He had us go in groups of 4 people with fire extinguishers to try to put out the fire.  As their extinguishers ran out of fuel, others waiting behind would take their place trying to put out the fire.

We would chase the fire around the structure trying to put it out, but it wasn’t as easy as you would think.  If you didn’t completely suffocate it by hitting it from many different directions and in a pattern from one end to the other just right, the fire would dodge around the spray from the extinguishers to be right back where you started.  By the time we had used up all the extinguishers, we may have put the fire out about 3 times.

Rubber boots… I kept thinking…. my feet are getting hot…  You couldn’t hardly get close enough to the fire to use your fire extinguisher without getting your eyebrows singed.  I was always known for having long eyelashes, and I thought I could hear them sizzle as they brushed against my safety glasses.

That’s when they pulled the fire hose out of the fire box that was there next to the fire hydrant.  All over the plant grounds there were these red boxes.  They are lined up alongside the long conveyor belt from the coal yard to the plant (about 1/2 mile).  They were also lined up around the two silver painted million gallon number 2 Diesel tanks.  They were just about everywhere you looked (come to think of it).

I remember Summer Goebel when she was a new plant engineer one time asked me when she had first arrived, “What are all those red boxes out there?” (she was pointing out the window of the Engineer’s office).  I told her they each contained fire hose and a valve wrench to open up the fire hydrant.  I neglected to add that they also provided great shade for all the Jack and Jill rabbits that inhabited the plant grounds, which doubled as a wild life preserve.

An outdoor Power Plant fire hose cabinet and Metallic Rabbit shade tree

So, we were going to use the fire hose!  That sounded like more fun.  That is until the one guy said to the other guy (more using hand and face signals — like putting his thumb up and winking) “open ‘er up”  — so, he was using “slang” hand and face signals…

That’s when the real training began.  First of all, we all backed up because as the flames grew on their structure, the heat literally talked directly to your legs and magically told them…. “back up, or else…”  so, now that we were standing a good 50 feet away from the fire, we lined up in a row on the fire hose.

4 of us.  Four hefty Brawny Power Plant men… (well, 3 hefty brawny  power plant men, and one scrawny little runt of a summer help who actually thought he could be measured alongside them),  Isn’t that a bit much for this one 4 inch fire hose? (or was it just 3 inches?).  There were two hoses actually being used.  One to create a wide barrier of water to protect us from the heat, and another hose to shoot water through the barrier into the fire.

A couple of guys manned the large roll around fire extinguisher.  Here is an actual picture of the OSU Training Service training a group of employees at a work site to fight fires to give you a picture of what we faced:

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

Notice the two different types of sprays in the picture.

Like I said, these guys aren’t called the best Fire Trainers because they have pretty pamplets.  so, the first time I slipped in the mud, I thought… hmm… I suppose the rainsuit would have kept all that mud from coming into contact with my jeans, and my shirt and my ego.

Well, the most fascinating thing was that we could walk up real close to this intense fire and the wide spray of water sheltered us from the heat.

This is how you open the nozzle to create the wide barrier spray

Then with the large fire extinguisher on wheels, you could open it up on the fire by standing behind this barrier and shoot the chemicals right through the water onto the fire, and it would quickly and incredibly put out that tremendous fire when it was done right.  The other fire hose that was spraying through the barrier of water was used to cool everything down so that the fire didn’t spring right back up.  the water wasn’t going to put out an oil fire.

Anyway, not long after our first of many fire fighting training sessions that we had throughout the years, the night that we were actually fighting the dragon in the boiler (See the Post, “Where do Knights of the Past go to Fight Dragons Today“), the Control Room came over the gray phone (PA system) saying that there was a fire on the turbine room floor.

A bunch of power plant he-men dropped the lance they were using to pierce the dragon and ran off to fight the fire.  It turned out to be a barrel full of oily rags that had spontaneously combusted.  The fire refused to go out for a long time.  It kept re-igniting until the contents had completely burned up.

I remained in the bottom ash area as I was still reeling from the steaming hot water that had been spewed all over me.  A little while later the men were back ready to grab the lance and go back to work on the boiler around 10pm (this after a full day of coal cleanup from 8am that morning).

The one important topic that they ingrained into our minds while we were taking the training was that you have to know when the fire is too big to fight.  We had learned what our equipment could do and what it couldn’t do.  So, we had the knowledge to realize that if the fire is too big, then it is time to get out of there and call the professionals.  The only problem was that the nearest professionals were about 20 minutes away.  A lot can burn down in that amount of time…. but that is a story for another time.  I see the grin on the power plant men’s faces.  They know what I am talking about.

Comments from Previous Repost:

  1. coffeegrounded  October 6, 2014

    I am extremely proud of my 2006 graduate of OSU’s Fire Protection program! My son-in-law went on to establish his own fire protection services company in Northern California.

    Go OSU!

    Very interesting article; thanks for sharing. I’m forwarding this post to my #1 son. Seeing this article and knowing the integrity of the program is gratifying and greatly appreciated. (My own parents lost their lives in a house fire.) Thanks for spreading the word on fire safety.

  2. Ron Kilman October 7, 2014

    Great story and reminder. After your original post I checked our little fire extinguisher in our kitchen. The pressure gauge was still in the green but it was 10 years old. So we decided to see if it still worked. It did – emptied all the chemical with good pressure. We replaced it with a new one and my wife got some “hands on” experience. Thanks for the reminder.

Hot Night on the Power Plant Precipitator

Scott Hubbard and I weren’t too sure why we had been called out that night when we met at the Bowling Alley on Washington Street at two o’clock in the morning in Stillwater Oklahoma to drive out to the coal-fired Power Plant in North Central Oklahoma.  Something about a fire on the top of the precipitator.

I was glad that Scott was driving instead of me when I climbed into his pickup and he began the 20 mile journey up Highway 177.  I wasn’t quite awake yet from the phone call at 1:45 am telling me that there was a fire on the Unit 1 precipitator roof and they were calling Scott and I out to put it out.  I figured if there was a fire it should be put out long before the 45 minutes it takes me and Scott to arrive at the plant.

We had all been trained to fight fires this size, so it didn’t make sense why we had to go do this instead of the operators.

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

My head was still swimming from the lack of sleep when we arrived at the plant, and headed to the Control Room to find out more about the fire we were supposed to fight.  The Shift Supervisor explained that there was an oil fire under one of the high voltage transformers next to some high voltage cables, and the operators that were on duty didn’t feel comfortable climbing under the transformer stands to try and put it out because of high voltage cable tray that ran alongside the fire (ok, now it made sense.  Electricity was involved.  Electricians had to work on anything that had an electric cable attached even if it was a fire).

The size fire extinguisher you would find in your home

The size fire extinguisher you would find in your home.  The ones we used were bigger

The operators had already brought a number of fire extinguishers appropriate to putting out an oil fire to the precipitator roof, and they had an SCBA (Self Contained Breating Apparatus) waiting there as well.

Man wearing an SCBA

Man wearing an SCBA from Google Images

Scott and I went to the Electric Shop to get a couple of pairs of asbestos gloves just in case we needed them.

Asbestos Gloves worn when putting hot bearings on a motor shaft (for instance)

Asbestos Gloves worn when putting hot bearings on a motor shaft (for instance)

When we arrived on the precipitator roof we could smell the fire smoldering right away.  The operator explained that some oil soaked insulation was on fire under the transformer stand for Transformer 1G9 and that he had tried to put it out using the extinguisher, but since the transformer oil was soaked into the bricks of insulation, it didn’t seem to do any good.

The transformer stands are about 18 inches tall, so climbing under them reminded me of the time I was sandblasting the water treatment tanks and Curtis Love turned off my air (see the post:  “Power Plant Safety as Interpreted by Curtis Love“).  This time I had a self-contained breathing apparatus, so I was in control of my own air… only there would only be about 30 minutes of air in the tank.

After assessing the situation Scott and I decided that the only way to put the fire out was to remove the blocks of insulation that were burning.  This meant that I had to lay down under the precipitator transformers and come face to face with the burning insulation and pull them out while wearing the asbestos gloves and put them in a barrel.

The plan was that we would then lower the 55 gallon barrel down to the ground and extinguish the fire by filling the barrel with water.

Barrel of LPS Electro Contact Cleaner

A barrel this size, only it was empty and the top was removed

The precipitator is on the outlet end of the boiler.  The boiler exhaust blows through the precipitator and the ash in the exhaust is removed using static electricity generated by the large transformers on the precipitator roof using up to 45,000 volts of electicity.  When the precipitator is on, the roof is generally a warm place to be.

When a person is laying on the insulation under a transformer, the temperature is somewhat higher as the heat is trapped in the enclosed space between two enclosures called “Coffin Houses” (how appropriate).  When the insulation is soaked with burning oil, the temperature seemed to rise significantly.  Luckily the insulation was not fiberglass as you may have in your attic, because I was wearing nothing but a tee shirt and jeans.  So, I was not subject to the itching I would have if the insulation had been fiberglass.

I had turned the air on the SCBA without using the “Postive Pressure” setting.  That meant that when I inhaled, I pulled air from the air tank, but the air didn’t apply pressure on the mask to keep out the bad air.

I did that because, this looked like it was going to be a long job and I wanted to conserve the air in the tank, and I found that on this setting I was not breathing the smoke pouring up around my face.  Otherwise I would have reached down to the valve on my belt and changed the setting to positive pressure.

I kept wondering while I was lying there with my face a few inches from the smoldering blocks of insulation why I was so calm the entire time.  The hot temperature had caused my sweat reflex to pour out the sweat so I was quickly drenched.  I would just lay my head on the insulation as I reached into the hole I was creating and pulled a glowing brick of insulation out using the asbestos gloves.

I knew I was only half awake so I kept telling myself… “Pay attention.  Work slowly.  One step at a time.  I tried to work like Granny would when she was digging Taters on the Beverly Hillbillies (see the video below at 9:30 to 11:00 into the show):

In case you are not able to view the video above, try this link:  “Granny Digging Taters“.

It’s funny when you’re half dreaming the various things that come to mind.  I’m not sure how picking up smoldering bricks of insulation translated in my mind to Granny teaching beatniks how to pick “taters”…. but it did.

There was also something about this that reminded me of eating chocolate…. oh wait… that was probably left over from the dream I was having when the phone first rang back at the house.

For the next hour or so, I filled the barrels with the burning insulation and then lowered them down to the alleyway between Unit 1 and 2.  During this time I was still groggy from the lack of sleep and the entire process seemed like a dream to me.

I remember lying on my stomach next to the burning insulation.  Pulling the blocks out one at a time, layer by layer until I reached the precipitator roof underneath.  I placed each block of smoldering insulation in the barrel that had been lowered down by an overhead chain-fall near me.

When the barrel was about 3/4 full, we would work the chain fall over to the motorized hoist that would lower it down to the pickup truck bed 100 feet below.  When the barrel left the confines of the precipitator roof and the night air blew over the top of it, the insulation would burst into flames.  By the time the barrel landed in the back of the pickup truck the flames would be lighting up the alley way.

Scott doused the flames with a hose and an extinguisher and hauled the barrel of insulation off to a hazardous waste bin while I repeated the process with the next barrel that Scott attached to the hoist.

By the time we were through I smelled like something that crawled out of a damp fireplace.  My shirt and jeans were soaked with sweat and caked with pink insulation.  The SCBA was out of air after using it for an hour and we were ready to go home.

The operators said they would bring the empty extinguishers back to the plant and send the SCBA off to have it recharged.  We checked back in with the Shift Supervisor in the control room and told him we were heading for home.

I don’t remember which Shift Supervisor it was, though Gary Wright comes to my mind when I think about it.

Gene Day is the one standing on the right with the Orange shirt.

Gary Wright is the red haird man in the front row with the big round glasses

I don’t remember which operator was helping us on the precipitator roof either.  I would usually remember those things, but like I said, I was still dreaming during this entire process.

Normally at this time, since it was close to 3:30 in the morning, we would opt to stay over and just do some odd jobs until it was time to start work because the 6 hour rule would still require us to come back to work at the regular time (see the Post: “Power Plant Black Time and Six Hour Rule“).  Scott and I decided that we both needed a good shower and if we could catch even one hour of sleep before we had to head back out to work, that would help.

So, we climbed back into Scott’s truck and headed back to Stillwater to the bowling alley where I had left my car.  I don’t remember the drive home.  I don’t even remember taking off my shirt and jeans in the utility room where I walked in the house and placing them in the washing machine straightaway… though that’s what I did.

I know I took a shower, but all that was just part of the same dream I had been having since the phone rang earlier that night.  Usually I didn’t have trouble waking up when the phone rang in the middle of the night, but for some reason, this particular night, I never fully woke up.

Or… maybe it’s something else….  Could I have dreamed the entire thing?  Maybe I never did receive that call, and we didn’t have to go out to the plant in the middle of the night to put out a fire.  I mean… how crazy is that anyway?  Does it make any sense?

I suppose I will have to rely on Scott Hubbard to confirm that we really did fight that fire.  How about it Scott?

Scott Hubbard

Scott Hubbard

As Bill Gibson asked one time…. “Is the Fact Truer than the Fiction?”

Destruction of a Power Plant God

Sometimes we unknowingly end up worshiping things we never intend.  It isn’t until those things are destroyed before we realize what has happened.  We have a natural tendency to worship something.  It’s built into our DNA to worship God just as sure as the God Particle converts energy into matter and subsequently atoms into earth and water.  I’m not sure when my obsession began, but I definitely know the day when it was destroyed.  August 5, 1996.

The day of realization began as a normal day, as Scott Hubbard and I were driving to the plant.  It seemed like an extra dark morning considering it was the middle of the summer.  Perhaps it was because by this time we were working four tens, which meant we arrived at the plant before 7:00 am so we left Stillwater, Oklahoma at 6:15 to drive to the coal-fired Power Plant in North Central Oklahoma.

When we topped the overpass to the turnpike at 6:32 we thought we could see something strange at the Power Plant off in the distance.  The sun was going to rise in the next few minutes (at 6:42), yet, the sky seemed darker than usual.  It must have been a cloudy morning.

Power Plant at sunset

Power Plant at sunset (only we were arriving before sunrise)

We thought we could see red and blue flashing lights coming from one end of the plant.  It was only momentary, because once over the overpass, we were too low to see that section of the plant.  We weren’t really sure what we had seen.  It became even more confusing as we approached the entrance to the plant.

There seemed to be a little more activity happening at the front gate than usual.  there was a guard or an operator standing out there.  He waved us through the gate.  about 300 yards past the main gate, we had a clear view of the plant grounds laying before us as we made our way to the parking lot.  It was here that the significance of the flashing lights suddenly caused us to gasp. We were stunned into silence.

The area around the Unit 1 main power transformer was flashing with the red and blue lights of several fire trucks.  They seemed to be pulling away just about that time.  Some of the siding on the Turbine-Generator room was missing, some was blackened from smoke as it had poured out of the windows along the turbine room floor.  The real shock to me came as we approached the parking lot and I looked up through where a window used to be and I could see the sky.  I could see the sky where the T-G roof should have been.

We were directed to go into the maintenance garage to avoid the fire trucks who that were backing away.  We met with our team and Alan Kramer told us that there had been an explosion during the night when an overspeed test was being performed on the Unit 1 Boiler Feed Pump Turbine (BFPT).  The number one question we all wanted answered was quickly given to us…. No one was hurt in the explosion.

Alan mentioned that in our recent fire fighter training, we had learned that a large percentage of companies that have a major fire (such as ours) goes out of business within the next year.  That was not going to happen to us even though the damage was extensive.  Our job was going to put everything back to the way it was before the fire.

Here is the story as it happened, as much as I know:

The explosion occurred when an operator (I’ll let one of the operators remind me who it was) was running an overspeed test on the BFPT.  Suddenly he heard a loud pop and then the turbine winding up out of control.  He took off running and was around the corner of a concrete pillar when the turbine exploded.  The turning gear shot out like a top and flew across the mezzanine floor, hit the corner of the north stairway, and still spinning like a top, tore up the stairway as it made the turn halfway down and ended up in middle of the the T-G basement where it finally came to rest.  This turning gear weighs somewhere in the ballpark of a thousand pounds (I’m guessing).

Turning Gear

Turning Gear

At this point steam was shooting out of the Boiler Feed Pump Turbine.  The oil pumps that keep the bearings lubricated were spraying oil into the steam which burst into flames.  The flames shot up to the concrete floor 40 feet above.  The fire was so hot that it melted the metal structure holding up the floor and the rebar in the concrete.  The Turbine Room Floor literally melted away as the oil fire shot the flames up toward the roof another 80 feet above the turbine room floor  melting the roof as if it was butter.  The asbestos siding on the T-G floor was falling off because the bolts that held them to the brackets literally melted away.

The same reservoir that feeds the oil to the the Boiler Feed Pump Turbine bearings also fed the Main Turbine Generator.  This is the same generator that makes the electricity that causes the light bulb to glow in your house when you turn it on.  The Main Turbine Generator tripped when the explosion occurred, as it should.  As it slowed down to a stop, the oil for the bearings was all gone.  It had been creating the large fire ball that was melting down the T-G floor.

Normally, when the Turbine-Generator comes to a stop, it is put on a turning gear while the shaft cools down otherwise the shaft will become warped under it’s own weight.  The Turning gear slowing rotates the turbine for a day or so while it cools.  Without bearing oil, the turning gear would not be able to turn the turbine generator.  The bearings require a layer of oil to function properly.

Unit 1 Turbine-Generator

Unit 1 Turbine-Generator

Charles Patton, one of the Maintenance foremen was called out, and he took cans of STP Oil Treatment and for hours poured them onto the bearings and manually rotated the 50 ton turbine generator (Ray, help me out with the actual weights).  Through the heroic efforts of Charles and others that were there to help, the Turbine Generator was spared from even more damage.

Charles Patton

Charles Patton

By the time we arrived that morning, the fire was out, things were cooling down.  Unit 2 was still running, and it was our job to keep it going.

Unit 2 Turbine-Generator

Unit 2 Turbine-Generator

As I walked out onto the T-G floor everything went into slow motion.  I don’t know if that has ever happened to you before.  There have been a few times in my life when I was in a near death situation where my surroundings all seem to switch into a slow motion mode.  I think it happens because your brain kicks into high gear in order to process what is happening and to put as much effort forward as possible to avoid danger.

The first time I think that happened to me was when I was with some friends climbing around on some cliffs by the Missouri River.  One boy was falling back after the ledge he was on gave way and was going to fall most likely to his death when everything switched into slow motion even before I realized what was wrong.  I was able to make quick decisions that allowed me to push him back onto the ledge and grab onto a branch that luckily kept me from the same fate.

When I walked onto the T-G floor and saw the devastation, I think my mind was trying to take everything in all at once.  The Turbine Generator was covered in soot and debris.  I flashed back to the days when I was a janitor and used to keep the turbines waxed so that they would shine.  It was at this moment that I realized I actually worshiped the Turbine Generators in a way similar to the way the religious cult worshiped the alpha-omega doomsday bomb in “Beneath the Planet of the Apes”.

Bomb Worshipers in Beneath the Planet of the Apes

Bomb Worshipers in Beneath the Planet of the Apes

The near destruction of the Turbine Generator made me realize the importance I had placed on it.  I felt as if I had almost lost my close friend like the boy climbing on the cliff.  I used to stand on the sides of the Turbines when I was a janitor with my dust mop and after spraying furniture polish on the mop, I would caress the turbines as if I was running my fingers through someone’s hair.

Like this only with a mop handle

Like this only with a mop handle

We began the clean up by taking fire hoses and washing down the siding on the Unit 2 side to try to bring some normalcy back to a surreal situation.  The soot didn’t just wash off.  Not long after we had dragged out the fire hoses and were blasting away at the siding, Alan Kramer asked Charles Foster and I to look at the air duct to the Instrument room on the north side of the Turbine room.  The room was getting too hot and the air conditioner seemed to have frozen.

We climbed into the air duct on the roof of the instrument room and replaced the filters that were packed with soot stopping the air flow for the Air Conditioner.  This seemed like one task in 100,000 that would need to be done to put this puzzle back together again.  All the electric cables that ran through the Unit 1 Mezzanine had melted away, everything had been utterly destroyed.

The thought was too overwhelming.  I felt like Scarlet O’Hara in “Gone With the Wind” when she said, “I can’t think about that right now.  If I do, I’ll go crazy.  I’ll think about that tomorrow.”

Vivian Leigh as Scarlett O'Hara in Gone With the Wind

Vivian Leigh as Scarlett O’Hara in Gone With the Wind

With everything on the T-G floor covered in soot, everyone was quickly black from head to toe.  Are clothes were now black.  We looked like Johnny Cash impersonators

Johnny Cash Man in Black

Johnny Cash Man in Black

literally with Al Jolsen Black Face as the soot was pitch black.

Al Jolson dressed in Black Face

Al Jolson dressed in Black Face (Google Image)

We had just climbed out of the air duct and were making our way to the electric shop when Glenn Rowland approached me and said, “You Lucky Dog!”  I thought he must be making a comment about my appearance seeing how I was covered in soot.  Then he explained.  “For the next 10 weeks you have to report to Oklahoma City to work on an SAP project.  You’re a lucky dog because you are going to miss all the fun of cleaning up this mess.”

Did I ever mention that I’m one of the luckiest people in the world?  Well.  I am.  I had just come to grips with my false God, and now I had been rescued from two and a half months of working in soot and grime to go work in an air conditioned office building in Oklahoma City.

Now for the hard part of the story to write about:

So, why did the Boiler Feed Pump Turbine fail the overspeed test?  What happened to cause the explosion?

The first attempt to place the blame where it didn’t belong was to blame Sonny Kendrick who had worked on the controls during the last outage.   The same person that would accuse me of purposely causing any little opacity problem on the precipitator even when I was on vacation, was now blaming Sonny Kendrick for the multi-million dollar destruction of the Turbine Room Floor.

Sonny Kendrick must have looked like an easy target.  A soft-spoken man that works alone most of the time.  No one really understands some of the things he works on.  Maybe they thought he wouldn’t be able to explain the changes he had made to the controls in enough detail in order to blame him for the explosion.  I use the word “target” because someone else had to be “blamed” for the explosion than the person responsible.  The person they picked as the “fall guy” was Sonny Kendrick:

Sonny Kendrick

Sonny Kendrick

You see… someone was directly responsible for the explosion.  Someone who continuously used “Risk Management” as an excuse to cut corners.  I wonder if everything was completely on the unconscious level, or did this person ever realize the impact of his decisions.  You see, I haven’t completely decided.

There appears to have been a conspiracy to cover up the truth about the explosion that took three months to recover.  The first clue was to try to blame Sonny Kendrick without any proof.  I don’t know if Sonny was eventually cleared as the fall guy because he was able to clearly show how all of his wiring changes had no impact on an overspeed test, or someone who knew about the actual cause threatened to come out with the truth if they continued to pursue Sonny as the fall guy.  You see… there was more to this equipment failure than met the eye.

The turbine exploded because the coupling to the pump shattered.  That’s the part that connects the steam turbine to the boiler feed pump.  When the coupling broke the turbine, no longer having any resistance, began to rotate at a rate much faster than it was ever designed to rotate until it flew apart.

A large coupling

A large coupling

It was known at the end of the last outage that the coupling was damaged.  It would have delayed bringing the unit online another 2 or 3 days in order change out the coupling.  In the name of “Risk Management” it was decided to “risk it” until the next outage.  The decision was made without using any type of risk assessment tool… obviously.

I know about the conversations that took place because one of the people involved confided in me.  The person that told me the details of the conversations said that even under oath he would never tell anyone else the truth.  This is the second clue that made me think that a concerted effort was made to cover up the knowledge that it was known that a faulty coupling was operating on the Boiler Feed Pump Turbine and it had been decided to leave it in place.  You see… everyone who was on the team that found the damage knew about it.

The third clue this was a “conspiracy to cover up the truth” was that when an investigation was performed to look into the cause of the explosion, the person responsible for keeping the bad coupling in place played a major role in the investigation.  Like the Fox guarding the Hen House.

Because the truth about the coupling never came to light, the insurance company ended up paying the entire bill for the outage.  It was ruled as “equipment failure”.  Our plant manager Bill Green remarked one day that we actually came out ahead when the insurance company paid for the outage, because they paid our lost revenue without taking all the operating costs into account.

I know sometimes that things just happen and sometimes bad things happen.  Sometimes when everything is done correctly, something still goes wrong.  I know that.  That is why when this explosion first happened it made me step back and think twice about the dangers lurking around a Power Plant.  A tremendously large amount of energy is being converted from coal into electricity.  Somewhere, some time, something is going to go wrong and someone is going to be hurt or killed.

That is also why when this explosion happened, it never occurred to me to place the blame on anyone.  To me it was just one of those things that happens every now and then.  My bubble of innocence was burst the day I heard about the decision to keep a defective coupling in place on such an important piece of equipment.

On one hand I was angry that someone would make a decision that could have ended with the death of an operator, on the other hand, I was relieved to know that accidents like this don’t just happen.  It was only when someone decided to cut corners that this explosion occurred.  It gave me a little of my faith back in the system.  When things are done right, we can work safely without the fear that something is likely to explode in our face.

All right, so I never really worshiped the Turbine Generator.  I just exaggerated that part a bit.  But let me ask this question… Who in this story did?  Who was it that was willing to sacrifice the life of an operator to keep from delaying the “go-live”?  Who thought that having the Generator produce electricity two or three days sooner than it should have been was more important?  That is the person that really needs to re-evaluate their priorities and take another look at which God they worship.

The question is never, “Is there a God?”  The real question is “Which God do you worship?”

Power Plant Men Fighting Fires for Fun — Repost

Originally Posted October 5, 2012:

The Coal Fired Power Plant where I worked first as a summer help, then as a janitor, a labor crew hand and finally as an Electrician is located about 20 miles north of Stillwater, Oklahoma.  It just so happened that Oklahoma State University in Stillwater has one of the leading Fire Protection and Safety schools in the country.  They offer Fire Service Training for companies who need to train their employees how to fight fires.  As a summer help I was fortunate enough to take the onsite training that they provided at the power plant about every other summer to train the employees how to put out difficult fires.

It does sound like a good idea considering that there was all this coal laying around that had the habit of spontaneously igniting into smouldering embers that could easily lead to a large raging ball of flames.  In fact, the Coal Yard heavy equipment operators had to driver their large dirt movers over and over the coal on the coal pile to pack it down because if it was exposed to too much air, it would develop hot spots that would turn into smouldering piles of coal that were nearly impossible to put out.

Dirt Mover full of coal

I have seen a spot smouldering on the coal pile where a water wagon would drench it with water over and over.  That only seemed to keep it from spreading as fast.  The only way to deal with it was to drag the burning coal off of the pile and let it burn itself out.

You would think that the OSU Fire Training Service would do a good job of teaching the employees the proper use of the fire extinguishers.  the plant was loaded with Fire Extinguishers, and they did.  As a summer help and labor crew hand, we would have to do a monthly inspection of all the plant extinguishers to check their pressures an initial the inspection sticker showing that we had been by to check it.  This was a practice that would later change to once each quarter when the Power Plant Men were strung out too thin and the labor crew no longer existed.  Even later, the operators inspected them as they made their rounds, since they walked by them during their shifts anyway.

The plant had more than just the regular chemical fire extinguishers, it had the larger roll-around type in a few places as well:

More than what is needed in your average kitchen

The Fire Training Service trained us to use this as well.  Actually, they motivated us to go out and buy fire extinguishers to put in our own homes.  Which came in handy for me one year when an air condition repairman was using a blow torch in my house to cut out the cooling coils but forgot to take out the filter first.

The moment I saw him light up his torch, I pulled out the extinguisher from under the sink and set it on the counter.  As I watched him, he suddenly started jerking back and forth.  I figured something was up, so I pulled the pin, and when he was finally able to pull the burning filter out of the air duct, I was ready to blast it with the extinguisher.  So, I gratefully thank the electric company for properly training us to use the handy dandy fire extinguishers that you might use around the house.

The size fire extinguisher you would find in your home

The size fire extinguisher you would find in your home

One important thing that you learn about the little extinguishers in your house is that they don’t really go very far before they run out of chemicals.  So, you have to get the job done quickly while the fire is still small and manageable.

When I first heard that we were going to be trained to fight fires the second summer I was at the plant as a summer help, I was pretty excited.  Wow… Great!!!  Fight Fires!  That sounds fun.  A day of watching safety videos and playing with fire extinguishers.  I didn’t realize at the time that there was a reason why OSU Fire Training Service was the best fire training school in the radius of about 1,000 miles.

Sure.  We watched the training videos.  We learned all about proper fire extinguisher care and maintenance.  We heard stories about how small fires turned into raging infernos that burned companies right out of business.  One thing I remember is that some large percentage of companies that have a major fire are never able to recover to the point that they go completely out of business.

If you need the exact percentage, I suggest you call up the OSU School of Fire Protection and Safety.  They probably have the latest statistic printed on their school lunch napkins, because these guys eat, drink and sleep fire safety.

Then, after they had impressed us with their Fire Safety Prowess, they said, “Let’s take about a 15 minute break, and we will meet outside just north of the water treatment plant where we will resume your lessons.  Oh, and bring your rubber boots and maybe a rain suit.”  Rain Suit?  What?  It’s about 100 degrees outside.  I wouldn’t mind getting a little wet I thought to myself. — The simpleminded summer help that I was at the time.

I would describe in detail to you how they had this obstacle course of staircases and pipes and other metal structures all sitting in a big tray.  It’s enough to say that it was quite a tangled mess of a contraption.

“Interesting.” I thought… Are we going to climb the staircase  and shoot the fire from up above with our handy dandy fire extinguishers which were lined up in a row off to one side?  Climbing over pipes to fight a fire under the stairs maybe…  Do we get to use the big roll around fire extinguisher that was there too?  This looks like it might be fun.

That was when the fun began.  One of the trainers turned a valve, and then I realized that there was a fairly large tank there also that was hooked up to the pipes that wound around the mocked up structure of a stairway and other obstacles in the large tray.  As he turned the valve, what looked like diesel or kerosene some petroleum product  came spraying out of various holes in the piping spraying everything in the tray drenching it with fuel.

This other guy had a long rod that he had lit like a large lighter only it was giant size, and after the fuel had been spraying out for a while, he lowered the flame down into the tray that now was beginning to fill up with some kind of oily substance.  He lit it and the flames quickly spread over all the structure.  He had us go in groups of 4 people with fire extinguishers to try to put out the fire.  As their extinguishers ran out of fuel, others waiting behind would take their place trying to put out the fire.

We would chase the fire around the structure trying to put it out, but it wasn’t as easy as you would think.  If you didn’t completely suffocate it by hitting it from many different directions and in a pattern from one end to the other just right, the fire would dodge around the spray from the extinguishers to be right back where you started.  By the time we had used up all the extinguishers, we may have put the fire out about 3 times.

Rubber boots… I kept thinking…. my feet are getting hot…  You couldn’t hardly get close enough to the fire to use your fire extinguisher without getting your eyebrows singed.  I was always known for having long eyelashes, and I thought I could hear them sizzle as they brushed against my safety glasses.

That’s when they pulled the fire hose out of the fire box that was there next to the fire hydrant.  All over the plant grounds there were these red boxes.  They are lined up alongside the long conveyor belt from the coal yard to the plant (about 1/2 mile).  They were lined up along around the two silver painted million gallon number 2 Diesel tanks.  They were just about everywhere you looked (come to think of it).

I remember Summer Goebel when she was a new plant engineer one time asked me when she had first arrived, “What are all those red boxes out there?” (she was pointing out the window of the Engineer’s office).  I told her they each contained fire hose and a valve wrench to open up the fire hydrant.  I neglected to add that they also provided great shade for all the Jack and Jill rabbits that inhabited the plant grounds, which doubled as a wild life preserve.

An outdoor Power Plant fire hose cabinet and Metallic Rabbit shade tree

So, we were going to use the fire hose!  That sounded like more fun.  That is until the one guy said to the other guy (more using hand and face signals — like putting his thumb up and winking) “open ‘er up”  — so, he was using “slang” hand and face signals…

That’s when the real training began.  First of all, we all backed up because as the flames grew on their structure, the heat literally talked directly to your legs and magically told them…. “back up, or else…”  so, now that we were standing a good 50 feet away from the fire, we lined up in a row on the fire hose.

4 of us.  Four hefty Brawny Power Plant men… (well, 3 hefty brawny  power plant men, and one scrawny little runt of a summer help who actually thought he could be measured alongside them),  Isn’t that a bit much for this one 4 inch fire hose? (or was it just 3 inches?).  There were two hoses actually being used.  One to create a wide barrier of water to protect us from the heat, and another hose to shoot water through the barrier into the fire.

A couple of guys manned the large roll around fire extinguisher.  Here is an actual picture of the OSU Training Service training a group of employees at a work site to fight fires to give you a picture of what we faced:

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

Notice the two different types of sprays in the picture.

Like I said, these guys aren’t called the best Fire Trainers because they have pretty pamplets.  so, the first time I slipped in the mud, I thought… hmm… I suppose the rainsuit would have kept all that mud from coming into contact with my jeans, and my shirt and my ego.

Well, the most fascinating thing was that we could walk up real close to this intense fire and the wide spray of water sheltered us from the heat.

This is how you open the nozzle to create the wide barrier spray

Then with the large fire extinguisher on wheels, you could open it up on the fire by standing behind this barrier and shoot the chemicals right through the water onto the fire, and it would quickly and incredibly put out that tremendous fire when it was done right.  The other fire hose that was spraying through the barrier of water was used to cool everything down so that the fire didn’t spring right back up.  the water wasn’t going to put out an oil fire.

Anyway, not long after our first of many fire fighting training sessions that we had throughout the years, the night that we were actually fighting the dragon in the boiler (See the Post, “Where do Knights of the Past go to Fight Dragons Today“), the Control Room came over the gray phone (PA system) saying that there was a fire on the turbine room floor.

A bunch of power plant he-men dropped the lance they were using to pierce the dragon and ran off to fight the fire.  It turned out to be a barrel full of oily rags that had spontaneously combusted.  The fire refused to go out for a long time.  It kept re-igniting until the contents had completely burned up.

I remained in the bottom ash area as I was still reeling from the steaming hot water that had been spewed all over me.  A little while later the men were back ready to grab the lance and go back to work on the boiler around 10pm (this after a full day of coal cleanup from 8am that morning).

The one important topic that they ingrained into our minds while we were taking the training was that you have to know when the fire is too big to fight.  We had learned what our equipment could do and what it couldn’t do.  So, we had the knowledge to realize that if the fire is too big, then it is time to get out of there and call the professionals.  The only problem was that the nearest professionals were about 20 minutes away.  A lot can burn down in that amount of time…. but that is a story for another time.  I see the grin on the power plant men’s faces.  They know what I am talking about.

Power Plant Men Fighting Fires for Fun — Repost

Originally Posted October 5, 2012:

The Coal Fired Power Plant where I worked first as a summer help, then as a janitor, a labor crew hand and finally as an Electrician is located about 20 miles north of Stillwater, Oklahoma.  It just so happened that Oklahoma State University in Stillwater has one of the leading Fire Protection and Safety schools in the country.  They offer Fire Service Training for companies who need to train their employees how to fight fires.  As a summer help I was fortunate enough to take the onsite training that they provided at the power plant about every other summer to train the employees how to put out difficult fires.

It does sound like a good idea considering that there was all this coal laying around that had the habit of spontaneously igniting into smouldering embers that could easily lead to a large raging ball of flames.  In fact, the Coal Yard heavy equipment operators had to driver their large dirt movers over and over the coal on the coal pile to pack it down because if it was exposed to too much air, it would develop hot spots that would turn into smouldering piles of coal that were nearly impossible to put out.

Dirt Mover full of coal

I have seen a spot smouldering on the coal pile where a water wagon would drench it with water over and over.  That only seemed to keep it from spreading as fast.  The only way to deal with it was to drag the burning coal off of the pile and let it burn itself out.

You would think that the OSU Fire Training Service would do a good job of teaching the employees the proper use of the fire extinguishers.  the plant was loaded with Fire Extinguishers, and they did.  As a summer help and labor crew hand, we would have to do a monthly inspection of all the plant extinguishers to check their pressures an initial the inspection sticker showing that we had been by to check it.  This was a practice that would later change to once each quarter when the Power Plant Men were strung out too thin and the labor crew no longer existed.  Even later, the operators inspected them as they made their rounds, since they walked by them during their shifts anyway.

The plant had more than just the regular chemical fire extinguishers, it had the larger roll-around type in a few places as well:

More than what is needed in your average kitchen

The Fire Training Service trained us to use this as well.  Actually, they motivated us to go out and buy fire extinguishers to put in our own homes.  Which came in handy for me one year when an air condition repairman was using a blow torch in my house to cut out the cooling coils but forgot to take out the filter first.

The moment I saw him light up his torch, I pulled out the extinguisher from under the sink and set it on the counter.  As I watched him, he suddenly started jerking back and forth.  I figured something was up, so I pulled the pin, and when he was finally able to pull the burning filter out of the air duct, I was ready to blast it with the extinguisher.  So, I gratefully thank the electric company for properly training us to use the handy dandy fire extinguishers that you might use around the house.

The size fire extinguisher you would find in your home

The size fire extinguisher you would find in your home

One important thing that you learn about the little extinguishers in your house is that they don’t really go very far before they run out of chemicals.  So, you have to get the job done quickly while the fire is still small and manageable.

When I first heard that we were going to be trained to fight fires the second summer I was at the plant as a summer help, I was pretty excited.  Wow… Great!!!  Fight Fires!  That sounds fun.  A day of watching safety videos and playing with fire extinguishers.  I didn’t realize at the time that there was a reason why OSU Fire Training Service was the best fire training school in the radius of about 1,000 miles.

Sure.  We watched the training videos.  We learned all about proper fire extinguisher care and maintenance.  We heard stories about how small fires turned into raging infernos that burned companies right out of business.  One thing I remember is that some large percentage of companies that have a major fire are never able to recover to the point that they go completely out of business.

If you need the exact percentage, I suggest you call up the OSU School of Fire Protection and Safety.  They probably have the latest statistic printed on their school lunch napkins, because these guys eat, drink and sleep fire safety.

Then, after they had impressed us with their Fire Safety Prowess, they said, “Let’s take about a 15 minute break, and we will meet outside just north of the water treatment plant where we will resume your lessons.  Oh, and bring your rubber boots and maybe a rain suit.”  Rain Suit?  What?  It’s about 100 degrees outside.  I wouldn’t mind getting a little wet I thought to myself. — The simpleminded summer help that I was at the time.

I would describe in detail to you how they had this obstacle course of staircases and pipes and other metal structures all sitting in a big tray.  It’s enough to say that it was quite a tangled mess of a contraption.

“Interesting.” I thought… Are we going to climb the staircase  and shoot the fire from up above with our handy dandy fire extinguishers which were lined up in a row off to one side?  Climbing over pipes to fight a fire under the stairs maybe…  Do we get to use the big roll around fire extinguisher that was there too?  This looks like it might be fun.

That was when the fun began.  One of the trainers turned a valve, and then I realized that there was a fairly large tank there also that was hooked up to the pipes that wound around the mocked up structure of a stairway and other obstacles in the large tray.  As he turned the valve, what looked like diesel or kerosene some petroleum product  came spraying out of various holes in the piping spraying everything in the tray drenching it with fuel.

This other guy had a long rod that he had lit like a large lighter only it was giant size, and after the fuel had been spraying out for a while, he lowered the flame down into the tray that now was beginning to fill up with some kind of oily substance.  He lit it and the flames quickly spread over all the structure.  He had us go in groups of 4 people with fire extinguishers to try to put out the fire.  As their extinguishers ran out of fuel, others waiting behind would take their place trying to put out the fire.

We would chase the fire around the structure trying to put it out, but it wasn’t as easy as you would think.  If you didn’t completely suffocate it by hitting it from many different directions and in a pattern from one end to the other just right, the fire would dodge around the spray from the extinguishers to be right back where you started.  By the time we had used up all the extinguishers, we may have put the fire out about 3 times.

Rubber boots… I kept thinking…. my feet are getting hot…  You couldn’t hardly get close enough to the fire to use your fire extinguisher without getting your eyebrows singed.  I was always known for having long eyelashes, and I thought I could hear them sizzle as they brushed against my safety glasses.

That’s when they pulled the fire hose out of the fire box that was there next to the fire hydrant.  All over the plant grounds there were these red boxes.  They are lined up alongside the long conveyor belt from the coal yard to the plant (about 1/2 mile).  They were lined up along around the two silver painted million gallon number 2 Diesel tanks.  They were just about everywhere you looked (come to think of it).

I remember Summer Goebel when she was a new plant engineer one time asked me when she had first arrived, “What are all those red boxes out there?” (she was pointing out the window of the Engineer’s office).  I told her they each contained fire hose and a valve wrench to open up the fire hydrant.  I neglected to add that they also provided great shade for all the Jack and Jill rabbits that inhabited the plant grounds, which doubled as a wild life preserve.

An outdoor Power Plant fire hose cabinet and Metallic Rabbit shade tree

So, we were going to use the fire hose!  That sounded like more fun.  That is until the one guy said to the other guy (more using hand and face signals — like putting his thumb up and winking) “open ‘er up”  — so, he was using “slang” hand and face signals…

That’s when the real training began.  First of all, we all backed up because as the flames grew on their structure, the heat literally talked directly to your legs and magically told them…. “back up, or else…”  so, now that we were standing a good 50 feet away from the fire, we lined up in a row on the fire hose.

4 of us.  Four hefty Brawny Power Plant men… (well, 3 hefty brawny  power plant men, and one scrawny little runt of a summer help who actually thought he could be measured alongside them),  Isn’t that a bit much for this one 4 inch fire hose? (or was it just 3 inches?).  There were two hoses actually being used.  One to create a wide barrier of water to protect us from the heat, and another hose to shoot water through the barrier into the fire.

A couple of guys manned the large roll around fire extinguisher.  Here is an actual picture of the OSU Training Service training a group of employees at a work site to fight fires to give you a picture of what we faced:

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

Notice the two different types of sprays in the picture.

Like I said, these guys aren’t called the best Fire Trainers because they have pretty pamplets.  so, the first time I slipped in the mud, I thought… hmm… I suppose the rainsuit would have kept all that mud from coming into contact with my jeans, and my shirt and my ego.

Well, the most fascinating thing was that we could walk up real close to this intense fire and the wide spray of water sheltered us from the heat.

This is how you open the nozzle to create the wide barrier spray

Then with the large fire extinguisher on wheels, you could open it up on the fire by standing behind this barrier and shoot the chemicals right through the water onto the fire, and it would quickly and incredibly put out that tremendous fire when it was done right.  The other fire hose that was spraying through the barrier of water was used to cool everything down so that the fire didn’t spring right back up.  the water wasn’t going to put out an oil fire.

Anyway, not long after our first of many fire fighting training sessions that we had throughout the years, the night that we were actually fighting the dragon in the boiler (See the Post, “Where do Knights of the Past go to Fight Dragons Today“), the Control Room came over the gray phone (PA system) saying that there was a fire on the turbine room floor.

A bunch of power plant he-men dropped the lance they were using to pierce the dragon and ran off to fight the fire.  It turned out to be a barrel full of oily rags that had spontaneously combusted.  The fire refused to go out for a long time.  It kept re-igniting until the contents had completely burned up.

I remained in the bottom ash area as I was still reeling from the steaming hot water that had been spewed all over me.  A little while later the men were back ready to grab the lance and go back to work on the boiler around 10pm (this after a full day of coal cleanup from 8am that morning).

The one important topic that they ingrained into our minds while we were taking the training was that you have to know when the fire is too big to fight.  We had learned what our equipment could do and what it couldn’t do.  So, we had the knowledge to realize that if the fire is too big, then it is time to get out of there and call the professionals.  The only problem was that the nearest professionals were about 20 minutes away.  A lot can burn down in that amount of time…. but that is a story for another time.  I see the grin on the power plant men’s faces.  They know what I am talking about.

Power Plant Men Fighting Fires for Fun

The Coal Fired Power Plant where I worked first as a summer help, then as a janitor and finally as an Electrician is located about 20 miles north of Stillwater, Oklahoma.  It just so happened that Oklahoma State University in Stillwater has one of the leading Fire Protection and Safety schools in the country.  They offer Fire Service Training for companies who need to train their employees how to fight fires.  As a summer help I was fortunate enough to take the onsite training that they provided at the power plant about every other summer to train the employees how to put out difficult fires.

It does sound like a good idea considering that there was all this coal laying around that had the habit of spontaneously igniting into smouldering embers that could easily lead to a large raging ball of flames.  In fact, the Coal Yard heavy equipment operators had to driver their large dirt movers over and over the coal on the coal pile to pack it down because if it was exposed to too much air, it would develop hot spots that would turn into smouldering piles of coal that were nearly impossible to put out.

Dirt Mover full of coal

I have seen a spot smouldering on the coal pile where a water wagon would drench it with water over and over.  That only seemed to keep it from spreading as fast.  The only way to deal with it was to drag the burning coal off of the pile and let it burn itself out.

You would think that the OSU Fire Training Service would do a good job of teaching the employees the proper use of the fire extinguishers.  the plant was loaded with Fire Extinguishers, and they did.  As a summer help and labor crew hand, we would have to do a monthly inspection of all the plant extinguishers to check their presures an initial the inspection sticker showing that we had been by to check it.  This was a practice that would later change to once each quarter when the Power Plant Men were strung out too thin and the labor crew no longer existed.

The plant had more than just the regular chemical fire extinguishers, it had the larger roll-around type in a few places as well:

More than what is needed in your average kitchen

The Fire Training Service trained us to use this as well.  Actually, they motivated us to go out and buy fire extinguishers to put in your own homes.  Which came in handy for me one year when an air condition repairman was using a blow torch in my house to cut out the cooling coils but forgot to take out the filter first.  The moment I saw him light up his torch, I pulled out the extinguisher from under the sink and set it on the counter.  As I watched him, he suddenly started jerking back and forth.  I figured something was up, so I pulled the pin, and when he was finally able to pull the burning filter out of the air duct, I was ready to blast it with the extinguisher.  So, I gratefully thank the electric company for properly training us to use the handy dandy fire extinguishers that you might use around the house.

One important thing that you learn about the little extinguishers in your house is that they don’t really go very far before they run out of chemicals.  So, you have to get the job done quickly while the fire is still small and manageable.

When I first heard that we were going to be trained to fight fires the second summer I was at the plant as a summer help, I was pretty excited.  Wow… Great!!!  Fight Fires!  That sounds fun.  A day of watching safety videos and playing with fire extinguishers.  I didn’t realize at the time that there was a reason why OSU Fire Training Service was the best fire training school in the radius of about 1,000 miles.

Sure.  We watched the training videos.  We learned all about proper fire extinguisher care and maintenance.  We heard stories about how small fires turned into raging infernos that burned companies right out of business.  One thing I remember is that some large percentage of companies that have a major fire are never able to recover to the point that they go completely out of business.  If you need the exact percentage, I suggest you call up the OSU School of Fire Protection and Safety.  They probably have the latest statistic printed on their school lunch napkins, because these guys eat, drink and sleep fire safety.

Then, after they had impressed us with their Fire Safety Prowess, they said, “Let’s take about a 15 minute break, and we will meet outside just north of the water treatment plant where we will resume your lessons.  Oh, and bring your rubber boots and maybe a rain suit.”  Rain Suit?  What?  It’s about 100 degrees outside.  I wouldn’t mind getting a little wet I thought to myself. — The simpleminded summer help that I was at the time.

I could describe in detail to you how they had this obstacle course of staircases and pipes and other metal structures all sitting in a big tray.  “Interesting.” I thought… Are we going to climb the staircase  and shoot the fire from up above with our handy dandy fire extinguishers which were lined up in a row off to one side?  Climbing over pipes to fight a fire under the stairs maybe…  Do we get to use the big roll around fire extinguisher that was there too?  This looks like it might be fun.

That was when the fun began.  One of the trainers turned a valve, and then I realized that there was a fairly large tank there also that was hooked up to the pipes that wound around the mocked up structure of a stairway and other obstacles in the large tray.  As he turned the valve, what looked like diesel or kerosene some petroleum product  came spraying out of various holes in the piping spraying everything in the tray drenching it with fuel.

This other guy had a long rod that he had lit like a large lighter only it was giant size, and after the fuel had been spraying out for a while, he lowered the flame down into the tray that now was beginning to fill up with some kind of oily substance.  He lit it and the flames quickly spread over all the structure.  He had us go in groups of 4 people with fire extinguishers to try to put out the fire.  As their extinguishers ran out of fuel, others waiting behind would take their place trying to put out the fire. 

We would chase the fire around the structure trying to put it out, but it wasn’t as easy as you would think.  If you didn’t completely suffocate it by hitting it from many different directions and in a pattern from one end to the other just right, the fire would dodge around the spray from the extinguishers to be right back where you started.  By the time we had used up all the extinguishers, we may have put the fire out about 3 times.

Rubber boots… I kept thinking…. my feet are getting hot…  You couldn’t hardly get close enough to the fire to use your fire extinguisher without getting your eyebrows singed.  I was always known for having long eyelashes, and I thought I could hear them sizzle as they brushed against my safety glasses.

That’s when they pulled the fire hose out of the fire box that was there next to the fire hydrant.  All over the plant grounds there were these red boxes.  They are lined up alongside the long conveyor belt from the coal yard to the plant (about 1/2 mile).  They were lined up along around the two silver painted million gallon number 2 Diesel tanks.  They were just about everywhere you looked (come to think of it).   I remember Summer Goebel when she was a new plant engineer one time asked me when she had first arrived, “What are all those red boxes out there?” (she was pointing out the window of the Engineer’s office).  I told her they each contained fire hose and a valve wrench to open up the fire hydrant.  I neglected to add that they also provided great shade for all the Jack and Jill rabbits that inhabited the plant grounds, which doubled as a wild life preserve.

An outdoore fire hose cabinet and Metalic Rabbit shade tree

So, we were going to use the fire hose!  That sounded like more fun.  That is until the one guy said to the other guy (more using hand and face signals — like putting his thumb up and winking) “open ‘er up”  — so, he was using “slang” hand and face signals…

That’s when the real training began.  First of all, we all backed up because as the flames grew on their structure, the heat literally talked directly to your legs and magically told them…. “back up, or else…”  so, now that we were standing a good 50 feet away from the fire, we lined up in a row on the fire hose.  4 of us.  Four hefty Brawny Power Plant men… (well, 3 hefty brawny  power plant men, and one scrawny little runt of a summer help who actually thought he could be measured alongside them),  Isn’t that a bit much for this one 4 inch fire hose? (or was it just 3 inches?).  There were two hoses actually being used.  One to create a wide barrier of water to protect us from the heat, and another hose to shoot water through the barrier into the fire.  A couple of guys manned the large roll around fire extinguisher.  Here is an actual picture of the OSU Training Service training a group of employees at a work site to fight fires to give you a picture of what we faced:

This is am actual picture of the OSU Fire Service training plant workers to fight fires.

Like I said, these guys aren’t called the best Fire Trainers because they have pretty pamplets.  so, the first time I slipped in the mud, I thought… hmm… I suppose the rainsuit would have kept all that mud from coming into contact with my jeans, and my shirt and my ego.

Well, the most fascinaing thing was that we could walk up real close to this intense fire and the wide spray of water sheltered us from the heat.

This is how you open the nozzle to create the wide barrier spray

Then with the large fire extinguisher on wheels, you could open it up on the fire by standing behind this barrier and shoot the chemicals right through the water onto the fire, and it would quickly and incredibly put out that trememdous fire when it was done right.  The other firehose that was spraying through the barrier of water was used to cool everything down so that the fire didn’t spring right back up.  the water wasn’t going to put out an oil fire.

Anyway, not long after our first of many fire fighting training sessions that we had throughout the years, the night that we were actually fighting the dragon in the boiler (See the Post, “Where do Knights of the Past go to Fight Dragons Today”), the Control Room came over the gray phone (PA system) saying that there was a fire on the turbine room floor.  A bunch of power plant he-men dropped the lance they were using to pierce the dragon and ran off to fight the fire.  It turned out to be a barrel full of oily rags that had spontaneously combusted.  The fire refused to go out for a long time.  It kept re-igniting until the contents had completely burned up.

I remained in the bottom ash area as I was still reeling from the steaming hot water that had been spewed all over me.  A little while later the men were back ready to grab the lance and go back to work on the boiler around 10pm (this after a full day of coal cleanup from 8am that morning).

The one important topic that they engrained into our minds while we were taking the training was that you have to know when the fire is too big to fight.  We had learned what our equipment could do and what it couldn’t do.  So, we had the knowledge to realize that if the fire is too big, then it is time to get out of there and call the professionals.  The only problem was that the nearest professionals were about 20 minutes away.  A lot can burn down in that amount of time…. but that is a story for another time.  I see the grin on the power plant men’s faces.  They know what I am talking about.